Operating Instructions, 07/2019, A5E33329501-AC
199
Discrete Input State (2.8.3.3.)
Sets the state of the discrete input (Discrete Input Number (2.8.3.2.) (Page 198)) that will
cause the Switch Alarm to activate.
Options
*
ON
OFF
Assigned Relay (2.8.3.4.)
Determines which relay (if any) will be activated when the Switch Alarm activates.
Options
*
NO RELAY
RELAY 1
RELAY 2
RELAY 3
Alarm State (2.8.3.5.)
Read only. Used to view the current state of the Switch Alarm.
Options
ACTIVE
INACTIVE
9.2.8.4 In-bounds Level Alarm (2.8.4.)
Reported when material level is within a user-defined range (see High Level Value (2.8.4.2.)
(Page 200) and Low Level Value (2.8.4.3.) (Page 200)).
Enable (2.8.4.1.)
Enables/disables In-bounds Level Alarm.
Options
ENABLED
*
DISABLED