Connecting
5.1 Connecting SITRANS LUT400
SITRANS LUT400
Operating Instructions, 07/2019, A5E33329501-AC
47
3. Separate from the device, knock out cable entry tab on blank lid:
a. With gasket in place, use snips to cut into lid on both sides of the cable entry knockout.
Use cutting guideline to cut from bottom of lid, up to bottom of groove (as shown below).
b. Once both sides of knockout have been cut through all layers of the lid (including the
gasket), pry upward with pliers on knockout to snap off plastic and uncover cable entry
hole.
c. Use sand paper if necessary to smooth any sharp edges.
d. Replace the blank lid on the enclosure.
Ingress protection of the enclosure is reduced to IP20, and Type 4X / NEMA 4X rating is
void when cable entry knock-out in the blank lid is removed.
Note
Installation location
An enclosure reduced to an IP20 rating and intended for use in nonhazardous locations
must be installed in an indoor location free of dust and moisture, or be installed in a
suita
bly rated field enclosure IP54 or better.
4. Connect the extension cable to the display connector on the terminal board. (If desired,
attach second extension cable to the other end of the first extension cable.)
5. Feed the free end of the extension cable through cable entry hole on blank lid.