EasyManuals Logo

Simplex 4100U Installation & Maintenance

Simplex 4100U
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
xv
Figure 8-2. Mounting onto the Power Distribution Interface......................... 8-4
Figure 8-3. Mounting into 4100 (legacy) Bay ............................................... 8-5
Figure 8-4. DIP Switch SW1......................................................................... 8-6
Figure 8-5. Class A Wiring ........................................................................... 8-8
Figure 8-6. Class B Wiring ........................................................................... 8-9
Figure 9-1. Service and Diagnostic Interface ...............................................9-2
Figure 9-2. Data Transfer Interface.............................................................. 9-2
Figure 9-3. Bootloader Interface ..................................................................9-3
Figure 10-1. Fan Control Module ................................................................. 10-5
Figure D-1. Volt/Ohm Meter Readings ........................................................D-1
Figure G-1. Earth Fault Search Example.....................................................G-8
Table 2-1 Master Controller LEDs 1 through 4 ............................................. 2-1
Table 5-1 4100 NIC & Media Cards – Electrical and Environmental
Specifications................................................................................ 5-7
Table 5-2 Wiring Distances.........................................................................5-12
Table 5-3 Dual Fiber Optic Cable Communications Distance Examples ...5-14
Table 5-4 Single Fiber Optic Cable Communications Distance
Examples using 4190-9010 Bi-Directional Couplers ..................5-14
Table 5-5 566-227 CPU Motherboard Wired Media Connections ..............5-16
Table 6-1 SPS Input and Output Specifications ...........................................6-2
Table 6-2 SPS Current Specifications .......................................................... 6-3
Table 6-3 Alarm Relay Card Jumper Positions............................................. 6-8
Table 7-1 Class A Wiring Distances .............................................................7-6
Table 7-2 Class B Wiring Distances .............................................................7-7
Table 8-1 IDNet Specifications .....................................................................8-3
Table 8-2 Cable Run Lengths .......................................................................8-8
Table 10-1 Switch/LED Format..................................................................... 10-4
Table 10-2 Switch Status ..............................................................................10-4
Table A-1 Card Addresses ............................................................................A-2
Table C-1 Acceptable Zone and Signal Circuit Meter Readings.................. C-2
List of Tables

Table of Contents

Other manuals for Simplex 4100U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4100U and is the answer not in the manual?

Simplex 4100U Specifications

General IconGeneral
Control Panel TypeAddressable Fire Alarm Control Panel
DisplayLCD
Power Supply120/240 VAC, 50/60 Hz
Max Signaling Line Circuits (SLC)2
Operating Temperature0°C to 49°C (32°F to 120°F)
Humidity Range10% to 93% non-condensing
Network CapabilityYes
Communication ProtocolRS-232, RS-485
Battery Backup24 VDC
NAC Outputs4
Signaling Line Circuits (SLCs)2
Power Supply Current3.0 A
Max Notification Appliance Circuits (NAC)4
Max Releasing Circuits4
Max Relay Circuits4
Communication PortsRS-232, RS-485