October 25, 2021 ©2021 Smartrise Engineering, Inc. All Rights Reserved Page 41
Sets delay between reaching zero speed and dropping
secondary brake on automatic operation
Sets delay between reaching zero speed and dropping the
secondary brake on inspection operation
When ON, disables ramping down command speed from
leveling speed to 1 fpm prior to dropping a run. This
option must be off for KEB drives.
When ON, disables stop sequence check for encoder
speed to read below 1 fpm prior to dropping the brake.