October 25, 2021 ©2021 Smartrise Engineering, Inc. All Rights Reserved Page 41
Menu
Description
EBrake Drop (Auto)
Sets delay between reaching zero speed and dropping
secondary brake on automatic operation
EBrake Drop (Insp)
Sets delay between reaching zero speed and dropping the
secondary brake on inspection operation
DIS Ramp Zero
When ON, disables ramping down command speed from
leveling speed to 1 fpm prior to dropping a run. This
option must be off for KEB drives.
DIS Hold Zero
When ON, disables stop sequence check for encoder
speed to read below 1 fpm prior to dropping the brake.
Turning this option off may increase floor level accuracy.