Page 48 ©2021 Smartrise Engineering, Inc. All Rights Reserved October 25, 2021
Menu
Description
Leveling Distance
Sets the distance from a floor at which the car
transitions to leveling speed on short profile runs
Speeds
Contract Speed
Maximum speed of the elevator
Inspection Speed
Set the speed at which the car runs for all Inspection
Modes
Access Speed
Sets the speed used during hoistway access
Learn Speed
Sets the speed used during hoistway learn operation
EPower Speed
Sets the maximum speed during emergency power
operation
Terminal Speed
Sets the speed the car will use while in inspection and
within the configured soft limit distance of a terminal
floor
Leveling Speed
Sets the speed used in automatic operation when
leveling into a floor. If leveling distance is zero, this has
no effect.
NTSD Speed
Set the target speed used during NTS. This option is
independent of the target speed on the drive and the
lowest value is used by the drive.
Min Accel Speed
Sets the minimum commanded speed used during
acceleration. Necessary for quick recovery from rollback
and cases of limited drive control at low speeds.
Min Relevel Speed
Sets the minimum commanded speed used when the
car is releveling.
Test A/D Speed
Sets the speed used during ascending/descending
overspeed tests
Test Buffer Speed
Sets the speed used during buffer test