C4 User Manual
Page 48 ©2021 Smartrise Engineering, Inc. All Rights Reserved October 25, 2021
Sets the distance from a floor at which the car
transitions to leveling speed on short profile runs
Maximum speed of the elevator
Set the speed at which the car runs for all Inspection
Modes
Sets the speed used during hoistway access
Sets the speed used during hoistway learn operation
Sets the maximum speed during emergency power
operation
Sets the speed the car will use while in inspection and
within the configured soft limit distance of a terminal
floor
Sets the speed used in automatic operation when
leveling into a floor. If leveling distance is zero, this has
no effect.
Set the target speed used during NTS. This option is
independent of the target speed on the drive and the
lowest value is used by the drive.
Sets the minimum commanded speed used during
acceleration. Necessary for quick recovery from rollback
and cases of limited drive control at low speeds.
Sets the minimum commanded speed used when the
car is releveling.
Sets the speed used during ascending/descending
overspeed tests
Sets the speed used during buffer test