Loading...
SNMP C
OMMANDS
3-65
link-up-down - Keyword to issue link-up or link-down traps.
The link-up-down trap can only be enabled/disabled via the CLI.
Default Setting
Issue authentication and link-up-down traps.
Command Mode
Global Configuration
Command Usage
If you do not enter an snmp-server enable traps command, no
notifications controlled by this command are sent. In order to
configure this device to send SNMP notifications, you must enter at
least one snmp-server enable traps command. If you enter the
command with no keywords, both authentication and link-up-down
notifications are enabled. If you enter the command with a keyword,
only the notification type related to that keyword is enabled.
•The snmp-server enable traps command is used in conjunction
with the snmp-server host command. Use the snmp-server
host command to specify which host or hosts receive SNMP
notifications. In order to send notifications, you must configure at least
one snmp-server host command.
Example
Related Commands
snmp-server host (3-64)
show snmp
Use this command to check the status of SNMP communications.
Default Setting
None
Console(config)#snmp-server enable traps link-up-down