EasyManuals Logo
Home>SMC Networks>Switch>6724AL2

SMC Networks 6724AL2 User Manual

SMC Networks 6724AL2
424 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #253 background imageLoading...
Page #253 background image
SNMP C
OMMANDS
3-65
• link-up-down - Keyword to issue link-up or link-down traps.
The link-up-down trap can only be enabled/disabled via the CLI.
Default Setting
Issue authentication and link-up-down traps.
Command Mode
Global Configuration
Command Usage
• If you do not enter an snmp-server enable traps command, no
notifications controlled by this command are sent. In order to
configure this device to send SNMP notifications, you must enter at
least one snmp-server enable traps command. If you enter the
command with no keywords, both authentication and link-up-down
notifications are enabled. If you enter the command with a keyword,
only the notification type related to that keyword is enabled.
•The snmp-server enable traps command is used in conjunction
with the snmp-server host command. Use the snmp-server
host command to specify which host or hosts receive SNMP
notifications. In order to send notifications, you must configure at least
one snmp-server host command.
Example
Related Commands
snmp-server host (3-64)
show snmp
Use this command to check the status of SNMP communications.
Default Setting
None
Console(config)#snmp-server enable traps link-up-down
Console(config)#

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks 6724AL2 and is the answer not in the manual?

SMC Networks 6724AL2 Specifications

General IconGeneral
BrandSMC Networks
Model6724AL2
CategorySwitch
LanguageEnglish

Related product manuals