Smart Energy
The following settings can be made and/or activated under temperature configuration:
Switch on when temperature is (C°):
greater
less
Runtime (min.):
If the appliance was activated because of the temperature threshold, it will be deactivated after
this time has passed, even if the minimum/maximum temperature has not been reached.
Minimum/Maximum temperature (C°) (depends on the selection for "Switch on when temperature
is (C°) greater or less"):
It is applied even if the appliances are activated because of a surplus or the temperature.
Surplus management and Time Control:
This Consumption determination is identical to Surplus management.
After selecting the Consumption determination, the following sections are to be configured:
Surplus
Time
The Surplus configuration (see Surplus management).
Up to two daily runtimes can be set in the time configuration. If only one runtime is needed, the second
one can be deleted by clicking on the trash can symbol.
Surplus management and Runtime Control:
This Consumption determination is identical to Surplus management.
After selecting the Consumption determination, the following sections are to be configured:
Surplus
Daily runtime
The Surplus configuration (see Surplus management).
The following settings can be made and/or activated under Daily runtime configuration:
Daily runtime [Min.] (this values is determined by the time from 0:00 to 23:59.)
Minimal
Exact
Maximal
Fill runtime from
Depending on the situation, it could happen that the period of time from the defined daily runtime
could not fulfilled with the surplus rule. In this case, it can be defined in this box at which time the
remaining daily runtime should be fulfilled. The process is also carried out when there is no surplus
available.
Minimum continuous switch on time [Min.]
Minimum continuous switch off time [Min.]
Max. switch on operations
The remaining daily runtime is completely fulfilled with the last switching run.

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals