138
Smart Energy
Note!
The daily runtime will be set to the value of the new day starting at 0:00 (midnight).
That is why it is not possible to have a runtime extending past the particular day. The
devices controlled in this section will be turned off at 0:00 (midnight).
Surplus matrix:
At least two and no more than three contacts have to be assigned to the switching group to use this func-
tion.
This Consumption determination is identical to Surplus management.
In the bottom section, there is a matrix to determine the output of the appliances and with which contacts
are linked to in the switching group.
Up to seven surplus levels can be created by clicking on the plus symbol.
Levels that are not needed can be deleted by clicking on the trash can symbol.
Surplus visualization:
With Surplus visualization, its own surplus threshold can be configured for every contact (1-8) assigned to
the group.
Note!
This function is only for the visualization and no loads may be switched on since the
Solar-Log™ would then have incorrect calculations which would lead to faulty switching
operations.
Production
With output visualization, its own output threshold can be configured for every contact (1-8) assigned to
the group.
Note!
This function is only for the visualization and no loads may be switched on since the
Solar-Log™ would then have incorrect calculations which would lead to faulty switching
operations.
Consumption
With Consumption visualization, its own consumption threshold can be configured for every contact (1-8)
assigned to the group.