DCR-PC101/PC101E
5-22
3. MR Adjustment
RadarWRadarWRadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject Not required
Measurement Point Adjusting remote commander
Measuring Instrument
Adjustment Page F
Adjustment Address 58, 5A to 65
Specified value 1 40 to C0
Specified value 2 03 to 78
Specified value 3 88 to FD
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: Perform Flange Back Adjustment after this adjustment.
Note 3: Check that the data of page: 0, address: 10 is 00.
Note 4: Check that the data of page: 6, address: 02 is 00.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER...................................................................CAMERA
Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 6 01 BD Press PAUSE button. (Note 5)
36 02
Check the data changes to
01.
4F
5A
5B
5C
5D
5F
5E
60
62
64
6F
5F
61
63
65
Note 5: The adjustment data will be automatically input to page:
F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
2 0 01 00
Check that the data of each
address satisfied the specified
value 1.
Check that the data of each
address satisfied the specified
value 2.
Check that the data of each
address satisfied the specified
value 3.