106 User Interface
2006792 Rev B 200228
Alarm Setting
Select to view and edit fault warning settings.
Select ON or OFF to turn each fault warning on and off.
WARNING: The alarm settings are set up by trained and qualified
personnel. Unauthorized tampering with these settings can result in unsafe
conditions, damage to the equipment, and voiding of the warranty.
Warning
Description
Gutter
“On” displays a warning message on the screen when the Ink stream
misses the Ink Return Gutter tube for more than 3 seconds. If this problem
persists for more than 10 seconds, the printer stops jetting automatically.
Temperature
Too Low
“On” displays a warning message on the screen when the ambient
temperature falls below 33.8°F (1°C).
Temperature
Too High
“On” displays a warning message on the screen when the ambient
temperature rises above 140°F (60 C).
Mixing Tank
Overflow
Status
“On” displays a warning message on the screen when the Mixing Tank
overflows. The printer stops printing and jetting automatically.
High Voltage
Leakages
“On” displays a warning message on the screen when a high voltage fault
occurs.
If the Alarm Settings have been changed by authorized and qualified personnel, select
Save.
When finished viewing Alarm Setting, select Close.