178 Warnings and Alarms
2006792 Rev B – 200228
Filter Assembly Warning
When the Filter Assembly countdown reaches 0 hours, “Filter Assembly 0 Hours” is displayed.
“Filter Assembly Not Detected” is displayed three seconds later. “Filter Assembly Fault” is
displayed in the Alarm Log (see “Alarm Log” on page 75).
The Main Filter Assembly needs to be replaced.
The JetStream will continue to run, but there will always be a “Service Recommended” alarm
once 6,000 hours have passed.
To address a Filter Assembly Warning:
1. Replace the Main Filter Assembly (see “Replacing the Main Filter Assembly” on page
159).
CAUTION – PROPERTY DAMAGE: Addressing a Filter Assembly
Warning should be performed by trained and qualified personnel. If in
doubt, contact your certified Squid Ink distributor.