097-93100-01 Revision C – February, 2010 TimeCreator 1000 Users Guide 183
Appendix B Command Descriptions and Communications Interface
CLI Commands
Level : User, Power-User and Admin
Set Alarm-Threshold
Use this command to provision the set and clear alarm thresholds for MTIE-35,
Jitter, MTIE-35, MTIE-t, and FER on the specified port. The threshold can be set for
all ports or an individual port.
Command Syntax:
To set the alarm threshold for Jitter:
set alarm-threshold jitter [port#|all] [set|clear] <value>
To set the alarm threshold for MTIE-35:
set alarm-threshold mtie-35 [port#|all][set|clear] <value>
To set the alarm threshold for MTIE-t:
set alarm-threshold mtie-t [port#|all][set|clear] <value>
To set the alarm threshold for FER:
set alarm-threshold fer [port#||all][set|clear] <value>
Range:
Jitter: 5000 - 10,000,000
MTIE-35: 5000 - 10,000,000
MTIE-t: 5000 - 10,000,000
FER: 5 - 10,000
Example 1:
To set the alarm threshold for Jitter on Port 5 to a value of 50,000:
tc1000>set alarm-threshold jitter port 5 set 50000
Example 2:
To set the alarm threshold for MTIE-35 on Port 6 to a value of 100,000:
tc1000>set alarm-threshold mtie-35 port 6 set 100000
Example 3:
To set the alarm threshold for MTIE-t on Port 7 to a value of 100,000:
tc1000>set alarm-threshold mtie-t port 7 set 100000
Example 4:

Table of Contents

Other manuals for Symmetricom TimeCreator 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeCreator 1000 and is the answer not in the manual?

Symmetricom TimeCreator 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeCreator 1000
CategoryServer
LanguageEnglish

Related product manuals