Preventive Maintenance and Fault-finding
Instruction Manual: evolution 5000 E5710 and E5720 Encoder Page 6-11
ST.TM.E10074.1
Table 6.3: Rate Buffer Settings
E5710/E5720 Setting Alteia Setting
PRO IRD SMALL -
Alteia only MEDIUM MEDIUM
Alteia and PRO IRD SMALL SMALL
6.7 Field/Frame Pictures
Some Receivers are unable to decode field pictures. Select Frames in the
Field/Frame Option. Does the fault clear? If not, contact Customer
Services.
6.8 Power Supply Problems/Green LED on Front
Panel Unlit
6.8.1 Symptoms
WARNING...
DO NOT ATTEMPT TO SERVICE THE POWER SUPPLY UNIT AS OPENING OR REMOVING
COVERS MAY EXPOSE DANGEROUS VOLTAGES OR OTHER HAZARDS. REFER ALL SERVICING
TO SERVICE PERSONNEL WHO HAVE BEEN AUTHORISED BY TANDBERG TELEVISION.
Use the following techniques to fault-find the Encoder according to the
observed symptom(s) when a power supply failure is suspected.
6.8.2 Power LED Unlit
If the Encoder Power LED is unlit, fault-find the problem as detailed in
Table 6.4.