119
FUNCTION SETTING USING SETTINGS
TopoMap Scale -
Adjustable Step
Set by ten-key display.
Step when the scale type of topo-map is Adjustable
is set. 0.25D to 2.50D (changeable with 0.25D steps)
1.50 149
TopoMap Scale -
Absolute Step
Set by ten-key display.
Step when the scale type of topo-map is Absolute is
set. 0.5D to 2.50D (changeable with 0.5D steps)
1.50 149
TopoMap
Overlay -
Cross Scale
ON
When analysis results are initially displayed,
topo-map overlay (cross scale) is displayed.
ON 150
OFF
When analysis results are initially displayed,
topo-map overlay (cross scale) is not displayed.
TopoMap
Overlay -
Angle Scale
ON
When analysis results are initially displayed,
topo-map overlay (angle scale) is displayed.
ON 150
OFF
When analysis results are initially displayed,
topo-map overlay (angle scale) is not displayed.
TopoMap
Overlay -
mm Grid Scale
ON
When analysis results are initially displayed,
topo-map overlay (mm grid scale) is displayed.
OFF 150
OFF
When analysis results are initially displayed,
topo-map overlay (mm grid scale) is not displayed.
TopoMap
Overlay -
Pupil
ON
When analysis results are initially displayed,
topo-map overlay (pupil) is displayed.
OFF 150
OFF
When analysis results are initially displayed,
topo-map overlay (pupil) is not displayed.
TopoMap Scale -
Kerato Axis
None KRT axis of topo-map is not displayed.
None 150
Sim-K axis KRT axis of topo-map is displayed.
Type of
optotypes
Landolt ring Select the Landolt ring for the optotypes.
Landolt
ring
151
Snellen chart Select the Snellen chart for the optotypes.
Method of
displaying
eyesight value
of simulation
Fraction
The eyesight value of simulation is indicated
in fraction.
Fraction 151
Decimal number
The eyesight value of simulation is indicated
in decimal number.
Optotype of Sim-
ulation 1 (Upper)
Set by ten-key display.
Optotype of Simulation 1 (upper) is set.
10 to 200 (changeable with 10 steps)
100 151
Optotype of Sim-
ulation 2 (Middle)
Set by ten-key display.
Optotype of Simulation 2 (middle) is set.
10 to 200 (changeable with 10 steps)
40 151
Optotype of Sim-
ulation 3 (Lower)
Set by ten-key display.
Optotype of Simulation 3 (lower) is set.
10 to 200 (changeable with 10 steps)
20 151
Optotypes
direction
Upper Direction of the optotypes is set to Upper.
Right 152
Lower Direction of the optotypes is set to Lower.
Right Direction of the optotypes is set to Right.
Left Direction of the optotypes is set to Left.
Normalize
destiny of
simulations
ON Normalization of brightness in Simulation is set.
OFF 152
OFF Normalization of brightness in Simulation is not set.
Sph Step
0.25D
Display step of spherical/corneal refractive power is
set to 0.25D
0.25D 1520.12D
Display step of spherical/corneal refractive power is
set to 0.12D.
0.01D
Display step of spherical/corneal refractive power is
set to 0.01D.
Cyl Step
0.25D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.25D.
0.25D 1520.12D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.12D.
0.01D
Display step of cylindrical refractive power/corneal
astigmatic power is set to 0.01D.
Axis Step
1°
Display step of astigmatic axis/corneal astigmatic
axis is set to 1
°.
1 152
5°
Display step of astigmatic axis/corneal astigmatic
axis is set to 5
°.
Set item display Setting Change button Set contents Initial value Page