TestingtheLiftControlValveSolenoidValveCoil(continued)
4.Useamultimeter(ohmssetting),measuretheresistancebetweenthe2
connectorterminalsonthesolenoidvalvecoil.Thecorrectresistancefor
thesolenoidcoilisidentiedintheSolenoidValveCoilSpecicationsTable
(page6–64).
SolenoidValveCoilSpecicationsTable
SolenoidValveCoil
DiameterHeightResistance
SV135.8mm(1.41inches)36.3mm(1.43inches)
8.8ohms
SV246.7mm(1.84inches)49.9mm(1.96inches)
7.1ohms
5.Ifthesolenoidcoilresistanceisincorrect,replacethesolenoidcoil;referto
theLiftControlValveSolenoidValveCoils(MachineSerialNumberabove
311000000)(page6–76).
6.Aftertestingthecoils,connectthewireharnesselectricalconnectortothe
solenoidvalvecoil.
ElectricalSystem:TestingtheElectricalComponents
Page6–64
Groundsmaster
®
3280-D/3320