IT2200 Reader System with Multimode Capability Installation & Maintenance/Service Guide
C-4
Table C-2 IT2020 Reader Logic Card Power Consumption
Environmental Specifications
The IT2020 Reader Logic Card can withstand the environmental tolerances shown in
Table C-3.
Table C-3 IT2020 Reader Logic Card Environmental Tolerances
Physical Specifications
Table C-4 lists the physical specifications of the IT2020 Reader Logic Card.
Table C-4 IT2020 Reader Logic Card Physical Specifications
Component +5 VDC +12 VDC
ISA PWA 500 mA
Encoder/Decoder/TDM Module 200 mA
I/O Module 75 mA 200 mA
Total: 775 mA 200 mA
Environment Tolerance
Dust Reader logic card is installed in host computer or lane
controller Therefore it is not exposed to external
environmental tolerances.Rain
Corrosive resistance
Shock 5 G ½-sine pulse, 10 ms duration, 3 axis
Vibration 1.0 G
rms
10-500 Hz
Operating
temperature
-20° to +55°C (-4° to +131°F)
Storage temperature -20° to +70°C (-4° to +158°F) ambient air temperature
Humidity 10 to 95% noncondensing
Characteristic Specification
Size 33.3 x 12.2 x 1.5 cm (13.1 x 4.8 x 0.6 in)
Weight 0.45 kg (1 lb)