System Technical Specifications
C-5
IT2611 RF Module
The IT2611 RF Module provides two-way RF communication between the IT2020
Reader Logic Card and any tags compatible with the IT2200 protocol. It relays data
and control signals from the reader logic card to the tags and relays tag responses to
the reader logic card.
Interfaces
The RF module has five external interfaces:
• Antennas—Three Type N socket connectors are used to connect the RF module to
the transmit, receive, and check tag antennas using low-loss, coaxial RF cables.
• Tag data/control—A 26-pin connector is used to connect the RF module to the
reader logic card using the data cable.
• Power—A 3-pin connector is used to connect the RF module to a power supply
(19-28 VAC @47-63 Hz or 16-28 V DC).
The data connector connects to the logic card to supply tag data information and com-
munication to the RF module.
Electrical Specifications
Table C-5 shows the electrical requirements for the IT2611 RF Module.
Table C-5 IT2611 RF Module Electrical Requirements
Environmental Specifications
The IT2611 RF Module can withstand the environmental conditions shown in Table
C-6.
Characteristic Specification
Input power 19-28 VAC @47-63 Hz or 16-28 V DC
Power consumption 40 W maximum
Power connection 3-pin connector