0D0!0+339+018+030+0.1+0.1+0.1<cr><lf>
Example 2:
S
tart a concurrent pressure, humidity and temperature measurement and request the data:
0C2!000503<cr><lf>
(measuremen
t ready in 5 seconds and 3 parameters available, for aC command device
address not sent as a sign of a completed measurement)
0D0!0+23.6+29.5+1009.5<cr><lf>
Example 3:
S
tart a precipitation measurement and request the data:
0M3!00006<cr><lf>
(6 parame
ters available immediately, thus the device address is not sent)
0D0!0+0.15+20+0.0+0.0+0+0.0<cr><lf>
Example 4
:
Start a supervisor measurement with CRC and request the data:
0MC5!00014<cr><lf>
(measuremen
t ready in one second and 4 parameters available)
0<cr><lf>
(measuremen
t completed)
0D0!0+34.3+10.5+10.7+3.366DpD<cr><lf>
Example 5:
Chapter 7 – Retrieving Data Messages
99