Parameter Factory Range Info Command
Auxiliary
solar sensor
gain
100000 0.000000001 … 1000000  
IB,G
Auxiliary level
sensor gain
1 0.000000001 … 1000000  
IS,G
Auxiliary level
sensor
opera
ting
range
1 0 = 0 to 2.5 V range  
IS,M
1 = 0 to 5.0 V range
2 = 0 to 10.0 V range
Auxiliary
temper
ature
averaging
1 0.5 … 3600  
IP,A
Table 63 Analog mA Output Parameters
Parameter Factory Range Info Command
Auxiliary
sensor
definitions
Order option
defined
1 = Tr pt1000 temperature Format:
0000001000000000
1 = mA output is in use
0 = mA output is o
Note that you write the
parame
ter format
0000001000000000 but
the unit answers
00000010&00000000
Note that the analog output
mode is used only inWXT532
with the mA output option.
IU,R
1 = Ra Aux. rain amount
1 = Sl Ultrasonic level sensor
1 = Sr Solar radiation
1 = Rt pt1000 resistance
0 = Reserved
1 = Analog output mode
0 = Reserved[& = Delimiter]
1 = Tr pt1000 temperature
1 = Ra Aux. rain amount
1 = Sl Ultrasonic level sensor
1 = Sr Solar radiation
1 = Rt pt1000 resistance
0 = Reserved
0 = Reserved
0 = Reserved
Wind speed
gain
Order option
defined
0.000000001 … 1000000 4 … 20 mA = 0.266667 (20
mA = 60 m
/
s)
0..20 mA = 0.333333 (20 mA
= 60 m/s)
SU,a
Appendix H – Configuration Parameters
209