Make the desired setting with the following command. Select the correct value/letter for the
set
ting fields.
Command format in ASCII and NMEA 0183:
aSU,R=x,I=x,S=x,H=x<cr><lf>
Command f
ormat in SDI-12;
aXSU,R=x,I=x,S=x,H=x!
R, I, S, H
The supervisor setting 
fields.
x
V
alue for the setting
<cr><lf>
Command terminator in ASCII and NMEA 0183
!
Command terminator in SDI-12
Example (ASCII and NMEA 0183, device address 0):
Disabling the heating and error messaging:
0SU,S=N,H=N<cr><lf>
0SU,S=N,H=N<cr><lf>
Example (
SDI-12, device address 0):
Changing the update interval to 10 seconds:
0XSU,I=10!0<cr><lf>
In SDI-12 mode a separ
ate enquiry (0XSU!) must be given to check the data content.
8.1.5 Composite Data Message (aR0)
You can define the parameters to be included in the composite data message aR0 in the
parameter selection fields of each parameter (aWU,R, aTU,R, aRU,R, and aSU,R).
When changing the bits 9-16 of the parameter selection of any sensor, you can shorten the
command b
y replacing the bits 1-8 with a single '&' character, see the examples.
Example (ASCII and NMEA 0183, device address 0):
Chapter 8 – Sensor and Data Message Settings
135