Example (ASCII):
0XZRU<cr><lf>
0TX,Rain reset<cr><lf>
Example (
SDI-12):
0XZRU!0<cr><lf> (= device address)
Example (NMEA 0
183):
0XZRU<cr><lf>
$WITXT,01,01,10,Rain reset*26<cr><lf>
7.1.3 Precipitation Intensity Reset (aXZRI)
This command resets the rain and hail intensity parameters Ri, Rp, Hi, and Hp.
C
ommand f
ormat in ASCII and NMEA 0183:
aXZRI<cr><lf>
Command format in SDI-12:
aXZRI!
a
Device address
XZRI
Precipitation intensity reset command
<cr><lf>
Command terminator in ASCII and NMEA 0183
!
Command terminator in SDI-12
The precipitation counter and precipitation intensity parameters are reset also when the
supply voltage is disc
onnected, the command aXZ is issued, precipitation counter reset
mode is changed, or when the precipitation/surface hits units are changed.
Example (ASCII):
Chapter 7 – Retrieving Data Messages
79