<cr><lf>
Command terminator in ASCII and NMEA 0183
!
Command terminator in SDI-12
The response depends on the communication protocol as shown in the examples.
Example (ASCII):
0XZ<cr><lf>
0TX,Start-up<cr><lf>
Example (
SDI-12):
0XZ!0<cr><lf> (=device address)
Example (NMEA 0
183):
0XZ<cr><lf>
$WITXT,01,01,07,Start-up*29
7.1.2 Precipitation Counter Reset (aXZRU)
This command resets the rain and hail accumulation and duration parameters Rc, Rd, Hc,
and Hd.
Command f
ormat in ASCII and NMEA 0183:
aXZRU<cr><lf>
Command f
ormat in SDI-12:
aXZRU!
a
Device address
XZRU
Precipitation counter reset command
<cr><lf>
Command terminator in ASCII and NMEA 0183
!
Command terminator in SDI-12
WXT530 Series User Guide M211840EN-D