a!
a
Device address
!
Command terminator
Response:
a<cr><lf>
a
Device address
<cr><lf>
Response terminator
Example:
0!0<cr><lf>
7.3.3 Change Address Command (aAb)
This command changes the device address. After the command has been issued and
responded t
o, the sensor is not required to respond to another command for one second to
ensure writing the new address to the non-volatile memory.
Command format:
aAb!
a
Device address
A
Change address command
b
Address to change to
!
Command terminator
Response:
b<cr><lf>