aXXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>
You can add the Id inf
ormation field in the supervisor data message to provide
identifying information in addition to the transmitter address. The information field is set
as part of the factory settings. You can only modify it with the Vaisala Configuration Tool.
More Information
‣
Supervisor Mes
sage (page 13
2)
‣
General Unit Settings (page 183)
6.4.2 Settings Fields
Parameter Description
a
Device address
XU
Device settings command in ASCII and NMEA 0183
XXU
Device settings command in SDI-12
[A]
Address: 0 (default) … 9, A … Z, a … z
[M]
Communication protocol:
A = ASCII, automatic
a = ASCII, automatic with CRC
P = ASCII, polled
p = ASCII, polled, with CRC
N = NMEA 0183 v3.0, automatic
Q = NMEA 0183 v3.0, query (= polled)
S = SDI-12 v1.3
R = SDI-12 v1.3 continuous measurement
[T]
Test parameter (for testing use only)
[C]
Serial interface:
1 = SDI-12
2 = RS-232
3 = RS-485
4 = RS-422
[I]
Automatic repeat interval for Composite data message: 1 … 3600 s, 0 = no automatic repeat
Chapter 6 – Connection Options
73