EasyManuals Logo

Vaisala WXT530 Series User Manual

Vaisala WXT530 Series
221 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
11.3 Environmental Conditions
Table 45 WXT530 Series Environmental Specifications
Property Description/Value
Operating temperature -52 ... +60 °C (-60 ... +140 °F)
Storage temperature -60 ... +70 °C (-76 ... +158 °F)
Relative humidity 0 ... 100 %RH
Pressure 600 ... 1100 hPa
Wind
1)
0 ... 60 m/s (134 mph)
IP rating IP65 (without mounting kit)
IP66 (with moun
ting kit attached)
1) Due to the measurement frequency used in the sonic transducers, RF interference in the 200 ... 400 kHz range can disturb
wind measuremen
t.
Select a heated sensor model if you operate the sensor in humid conditions.
Select a heated model if you operate the sensor in temperatures below 0 °C (+32 °F).
Make sure that you power the sensor after installation. Storing the sensor
outdoor
s without proper package or not powering up after installation can aect the
sensor's expected lifespan.
CAUTION!
Any temporary object (such as snow, ice, or a bird) that blocks the
observa
tion path between the ultrasonic transducer heads may lead to inaccurate or
incorrect measurements.
CAUTION!
Table 46 WXT530 Series Electromagnetic Compatibility
Applicable
Standard
Description Level tested
Performance
1)
CISPR 22 Radiated emissions 30 Hz ... 18 GHz Class B
Chapter 11 – Technical Specifications
161
sales@streamlinemeasurement.co.uk
01457-864334
www.streamlinemeasurement.co.uk

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaisala WXT530 Series and is the answer not in the manual?

Vaisala WXT530 Series Specifications

General IconGeneral
BrandVaisala
ModelWXT530 Series
CategoryTransmitter
LanguageEnglish

Related product manuals