EasyManua.ls Logo

Vaisala WXT530 Series - Start Concurrent Measurement with CRC (aCC); Send Data Command (aD)

Vaisala WXT530 Series
221 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goe
Correct three-character CRC for the ar1 command
IU~
T
hree-character CRC for the response message
<cr><lf>
Response terminator
Example of the other data query commands with CRC (when the device address is 0):
Parameter Description
Pressure, humidity and
t
emper
ature message query
0r2Gje<cr><lf>
Precipitation query 0r3Kid<cr><lf>
Supervisor query 0r5Kcd<cr><lf>
Combined message query 0rBVT<cr><lf>
Composite data message
query
0r0Kld<cr><lf>
In every case the response contains a three-character CRC before the <cr><lf>.
More In
formation
CRC-16 Computation (page 179)
CRC-16 Computation (page 179)
Sensor Configuration and Data Message Formatting (page 117)
7.2.11 Automatic Mode
When the automatic ASCII protocol is selected, the transmitter sends data messages at
user-configurable
update intervals.
T
he message structure is the same as with data query commands aR1, aR2,aR3 , and aR5.
You can choose an individual update interval for each sensor.
Example:
0R1,Dm=027D,Sm=0.1M<cr><lf>
0R2,Ta=74.6F,Ua=14.7P,Pa=1012.9H<cr><lf>
0R3,Rc=0.10M,Rd=2380s,Ri=0.0M,Hc=0.0M,Hd=0s,Hi=0.0M<cr><lf>
0R5,Th=76.1F,Vh=11.5N,Vs=11.5V,Vr=3.510V<cr><lf>
Example (
with CRC):
Chapter 7 – Retrieving Data Messages
89