8.
Sensor and Data Message
Settings
8.1
Sensor Configuration and Data
Message Formatting
This chapter lists the sensor configuration and data message formatting commands for all
communica
tions protocols:
• ASCII
• NMEA 0183
• SDI-12
You can also modify sensor and data message settings with the Vaisala Configuration Tool.
More Information
‣
Error Messaging/Text Messages (page 153)
8.1.1 Wind Sensor
WXT536 WXT535 WXT534 WXT533 WXT532 WXT531
✔ ✔ ✔
8.1.1.1 Checking the Settings (aWU)
W
ith the following command you can check the current wind sensor settings.
Command f
ormat in ASCII and NMEA 0183:
aWU<cr><lf>
Command f
ormat in SDI-12:
aXWU!
a
Device address
WU
Wind sensor settings command in ASCII and NMEA 0183
XWU
Wind sensor settings command in SDI-12
<cr><lf>
Command terminator in ASCII and NMEA 0183
Chapter 8 – Sensor and Data Message Settings