Table 60 Wind Parameters
Parameter Factory Range Info Command
Wind data
con
trols
Order option
defined
1 = Dn Direction minimum Format:1111110001001000
The first 8 are for combined
message and the last 8 for
composite message.
1 = Data is on
0 = Data is o
Note that you write the
parame
ter format
1111110001001000 but the unit
answers 11111100&01001000.
WU,R
1 = Dm Direction average
1 = Dx Direction maximum
1 = Sn Speed minimum
1 = Sm Speed average
1 = Sx Speed maximum
0 = Reserved
0 = Reserved[& = Delimiter]
0 = Dn Direction minimum
1 = Dm Direction average
0 = Dx Direction maximum
0 = Sn Speed minimum
1 = Sm Speed average
0 = Sx Speed maximum
0 = Reserved
0 = Reserved
Wind update
in
t
erval
5 1 … 3600 seconds
WU,I
Wind
av
eraging
time
3 1 … 3600 seconds
WU,A
Wind speed
calcula
tion
mode
1 1 = Max/min calculation 3 =
Gust/lull calculation
WU,G
Wind speed
unit
M M = m/s, K = km/h, S = mph,
N = knots
WU,U
Wind
direc
tion
oset
0 -180 ... 180
WU,D
NMEA format W T = XDR, W = MWV
WU,N
Sampling rate 4 1, 2, 4 Hz
WU,F