Appendix H. Configuration
Parameters
Table 58 General Parameters
Parameter Factory Range Info Command
Supervisor
settings
Order option
defined*
1 = Th Heating temperature Format:1111000011000000
First 8 are for combined
message and last 8 for
composite message.
1 = Data is on
0 = Data is o
Note that you write the
parame
ter format
1111000011000000 but the
unit answers:
11110000&11000000
* For the heated unit factory
the setting is
1111000011000000and for the
non-heated
0000000000000000
SU,R
1 = Vh Heating voltage
1 = Vs Supply voltage
1 = Vr 3.5 V reference voltage
1 = Id Information field
0 = R
eserved
0 = Reserved
0 = Reserved [& = Delimiter]
1 = Th Heating temperature
1 = Vh Heating voltage
0 = Vs Supply voltage
0 = Vr 3.5 V reference voltage
0 = Id Information
field
0 = R
eserved
0 = Reserved
0 = Reserved
Device
addres
s
0 0 … 9, A. … Z, a … z Address identifier
XU,A
Protocol
selection
Or
der option
defined
A = ASCII, automatic
XU,M
a = ASCII, automatic w. crc
P = ASCII, polled
p = ASCII, polled w. crc
N = NMEA, automatic
Q = NMEA, query
S = SDI-12, R
R = SDI, continuous meas
Test message 0 For test purposes
XU,T
Appendix H – Configuration Parameters
203