Command format:
aR5<cr><lf>
a
Device address
R5
Supervisor message query command
<cr><lf>
Command terminator
Example of the response (the parameter set is configurable):
0R5,Th=25.9C,Vh=12.0N,Vs=15.2V,Vr=3.475V,Id=HEL___<cr><lf>
a
Device address
R5
Supervisor message query command
Th
Heating temperature (C = °C)
Vh
Heating voltage (N = heating is o)
Vs
Supply v
oltage (V = V)
Vr
3.5 V reference voltage (V = V)
<cr><lf>
Response terminator
Id
Information field
The content of the parameter Id is a te
xt string which you can modify with the Vaisala
Configuration Tool. The field can include customer-specific, additional information. For more
information on changing the settings, see the Vaisala Configuration Tool online help for the
Info field in the Device Settings window.
Mor
e Information
‣
Supervisor Message (page 132)
7.2.8 Combined Data Message (aR)
This command requests all individual messages aR1, aR2, aR3, and aR5 with one
command.
C
ommand format:
aR<cr><lf>
WXT530 Series User Guide M211840EN-D
86