Example (SDI-12, device address 0):
0RU!0RU,R=11111100&10000000,I=60,U=M,S=M,M=R, Z=M,X=100,Y=100<cr><lf>
8.1.3.2 Setting Fields
Parameter Description
[R]
Parameter selection: This field consists of 16 bits defining the precipitation parameters
included in the data messages. The bit value 0 disables and the bit value 1 enables the
parameter.
Bits 1-8 determine the parameters included in the messages obtained with the following
commands:
•
ASCII: aR3 and ar3
• NMEA 0183: $--WIQ,XDR*hh
• SDI-12: aM3, aMC3, aC3, aCC3
• SDI-12 continuous: aR3 and ar3
Table 25 Precipitation Parameters Bits 1-8
Bit Description
1st bit (most
left)
Rc Rain amount
2nd bit Rd Rain duration
3rd bit Ri Rain intensity
4th bit Hc Hail amount
5th bit Hd Hail duration
6th bit Hi Hail intensity
7th bit Rp Rain peak
8th bit Hp Hail peak
& delimiter
Bits 9-16 determine the precipitation parameters included in the composite data messages
obtained with the follo
wing commands:
• ASCII:
• NMEA 0183: aR0, ar0
• SDI-12: aM, aMC, aC, aCC
• SDI-12 continuous: aR and aRC
WXT530 Series User Guide M211840EN-D
128