Device identifier
of the requester
WI
Device type identifier (WI = weather instrument)
Q
Defines the message as Query
XDR
T
ransducer measurement command
*
Checksum delimiter
hh
Two-character checksum for the query command.
<cr><lf>
Command terminator
The response includes the parameters activated in the data messages.
The parameter order in the output is as shown in the parameter selection setting field. See
8.
1 Sensor Configuration
and Data Message Formatting (page 117).
Response:
$WIXDR,a1,x.x1,u1,c--c1, ... ... ..an,x.xn,un,c--cn*hh<cr><lf>
$
Start of the message
WI
Device type identifier (WI = weather instrument)
XDR
T
ransducer measurement response identifier
a
1)
Transducer type for the first
transducer, see the following transducer table.
x.x
1)
Measurement data from the first transducer
u
1)
Units of the first transducer measurement, see the following transducer table.
c--c
1
First transducer identification (id). The transmitter’s address aXU,A is added as a base
number to the tr
ansducer id. (command aXU,A= [0 ... 9/A ... Z/a ... z].
1)
an
Transducer type for the transducer n, see the following transducer table.
x.xn
Measurement data from the transducer n
un
Units of the transducer n measurement, see the following transducer table.
c--cn
Transducer n id. the transmitter's address aXU,A is added as a base number to the
T
ransducer #ID. The address is changeable, see command aXU,A= [0 ... 9/A ... Z/
a ... z].
1)
*
Checksum delimiter
hh
Two-character checksum for the response
WXT530 Series User Guide M211840EN-D
106