Measurement Transducer ID Type
Rain accumulation 0 V
Rain duration 0 Z
Rain current intensity 0 R
Hail accumulation 1 V
Hail duration 1 Z
Hail current intensity 1 R
Rain peak intensity 2 R
Hail peak intensity 3 R
Heating temperature 2 C
Supply voltage 0 U
Heating voltage 1 U
3.5 V reference voltage 2 U
Information 
field 4 G
A
ux. rain (tipping bucket) 1 V
Solar radiation 3 U
Ultrasonic level sensor 4 U
Aux. temperature (pt1000) 3 C
To ensure correct XDR response, activate either hail accumulation or Aux. rain (tipping
bucke
t), not both at the same time.
Example of the XDR Query (all parameters of each sensor enabled and NMEA wind
forma
tter set to T):
$--WIQ,XDR*2D<cr><lf>
Example of the response when all the parameters of each sensor are enabled (NMEA wind
formatter set to T):
Wind sensor data
$WIXDR,A,302,D,0,A,320,D,1,A,330,D,2,S,0.1,M,0,S,0.2,M,1,S,0.2, M,2*57<cr><lf>
P, T
, and RH data
WXT530 Series User Guide M211840EN-D
108
sales@streamlinemeasurement.co.uk
www.streamlinemeasurement.co.uk