1. Select Configuration > Areas > Areas.
The following page will be displayed:
2. Click Edit to edit an existing area.
3. Click Add to add a new area. If the Installation Type is Domestic or Commercial, an area is
automatically added and the Edit Area Settings page is displayed.
Note that the area type for the new area is automatically set to Standard.
If the Installation Type is Financial, the following page is displayed and the area must be added
manually.
4. Enter a description for the new area and select an area type from one of the following:
- Standard – Suitable for most areas.
- ATM – Provides settings and defaults relevant to ATMs.
- Vault – Provides settings and defaults relevant to vaults.
- Advanced – Provides all area settings (Standard, ATM and Vault).
5. Click the Add button to add the area.
Configure the settings for each installation type as per the following sections.
Entry/Exit
Configure the following Entry/Exit settings:
Entry time The time period (in seconds) allowed for the user to UNSET the alarm after opening an entry/exit
zone of an armed system. The entry time applies to all entry/exit zones in that area (default: 45
seconds).
Exit time The time (in seconds) allowed for a user to leave a protected area before setting is complete. The
exit time will be counted down at the keypad as the buzzer beeps to indicate to the user that the
system will arm when the exit timer reaches zero. The exit time applies to all entry/exit zones in
that area (default: 45 seconds).
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 271 A6V10276959-d
11.2018