I
IANOSJP
I
loa
I
BATTERY INSPECTION
~
,
----------------------------
Charging method using a constant-voltage type charger
NOTE:
_
Measure the
open~circuit
Voltage should be measured
30
minutes
voltage prior
to
charging. after the machine is stopped.
Connect a charger and
AMP meter
to
the battery
and start charging.
YES
Make sure the current is
higher than the standard
r---------{
charging current written
on the battery.
Charge the battery until the battery's
charging voltage is
15
V.
NOTE:
_
Set the charging
time
at 20 hours
(maximum).
NO
This type
of
battery charger cannot
charge the
MF
battery. A variable
voltage charger is recommended.
Charger
Measure the battery
open~circuit
voltage after having left the battery
unused for more than
30
minutes.
12.8
V or more
~--
Charging is
complete.
12.7
V or less
---
Recharging
is
required.
Under 12.0 V
u_
Replace the battery.
Volt
meter
AMP
meter
~_IEJ
A
Charging
method
using a constant-current
type
charger
This
type
of
battery charger
cannot
charge
the
MF battery.
3 - 42