14.1 List of Parameters
14.1.2 List of Parameters
14-9
Pn00B
2
Application Function
Selections B
0000 hex
to
1121 hex
−
0000
hex
All
After
restart
Setup
−
Pn00C
2
Application Function
Selections C
0000 hex
to
0131 hex
−
0000
hex
−
After
restart
Setup
page
7-27
Pn00D
2
Application Function
Selections D
0000 hex
to
1001 hex
−
0000
hex
All
After
restart
Setup
page
5-34
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Operator Parameter Display Selection Reference
0 Display only setup parameters.
page 5-4
1 Display all parameters.
n.X
Motor Stopping Method for Group 2 Alarms Reference
0 Stop the motor by setting the speed reference to 0.
page 5-421
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.X).
2 Set the stopping method with Pn00A = n.X.
n.X
Power Input Selection for Three-phase SERVOPACK Reference
0 Use a three-phase power supply input.
page 5-14
1
Use a three-phase power supply input as a single-phase power
supply input.
n.X Reserved parameter (Do not change.)
n.X
Function Selection for Test without a Motor
Applicable
Motors
0 Disable tests without a motor.
All
1 Enable tests without a motor.
n.
X
Encoder Resolution for Tests without a Motor
Applicable
Motors
0Use 13 bits.
Rotary
1Use 20 bits.
2Use 22 bits.
3Use 24 bits.
n.X
Encoder Type Selection for Tests without a Motor
Applicable
Motors
0 Use an incremental encoder.
All
1 Use an absolute encoder.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
Overtravel Warning Detection Selection
0 Do not detect overtravel warnings.
1 Detect overtravel warnings.