14.1 List of Parameters
14.1.2 List of Parameters
14-17
Pn300 2
Speed Reference Input
Gain
150 to 3,000
0.01 V/
Rated
motor
speed
600 All
Immedi-
ately
Setup
page
6-19,
page
6-46,
page
8-88
Pn301 2 Internal Set Speed 1 0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1 min
-1
100 Rotary
Immedi-
ately
Setup
page
6-54
Pn302 2 Internal Set Speed 2 0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1 min
-1
200 Rotary
Immedi-
ately
Setup
page
6-54
Pn303 2 Internal Set Speed 3 0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1 min
-1
300 Rotary
Immedi-
ately
Setup
page
6-54
Pn304 2 Jogging Speed 0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1 min
-1
500 Rotary
Immedi-
ately
Setup
page
7-7
Pn305 2
Soft Start Acceleration
Time
0 to 10,000 1 ms 0 All
Immedi-
ately
Setup
page
6-24
Pn306 2
Soft Start Deceleration
Time
0 to 10,000 1 ms 0 All
Immedi-
ately
Setup
page
6-24
Pn307 2
Speed Reference Filter
Time Constant
0 to 65,535 0.01 ms 40 All
Immedi-
ately
Setup
page
6-24
Pn308 2
Speed Feedback Filter
Time Constant
0 to 65,535 0.01 ms 0 All
Immedi-
ately
Setup
page
8-76
Pn30A 2
Deceleration Time for
Servo OFF and Forced
Stops
0 to 10,000 1 ms 0 All
Immedi-
ately
Setup
page
5-33
Pn30C 2
Speed Feedforward
Average Movement
Time
0 to 5,100 0.1 ms 0 All
Immedi-
ately
Setup
page
8-86
Pn310
2
Vibration Detection
Selections
0000 hex
to
0002 hex
−
0000
hex
All
Immedi-
ately
Setup
page
6-98
Pn311 2
Vibration Detection Sen-
sitivity
50 to 500 1% 100 All
Immedi-
ately
Tuning
page
6-98
Pn312 2
Vibration Detection
Level
0 to 5,000
1 min
-1
50 Rotary
Immedi-
ately
Tuning
page
6-98
Pn316 2 Maximum Motor Speed 0 to 65,535
1 min
-1
10000 Rotary
After
restart
Setup
page
6-16
Pn324 2
Moment of Inertia Cal-
culation Starting Level
0 to 20,000 1% 300 All
Immedi-
ately
Setup
page
8-31
Pn380 2 Internal Set Speed 1 0 to 10,000 1 mm/s 10 Linear
Immedi-
ately
Setup
page
6-54
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Vibration Detection Selection
0 Do not detect vibration.
1 Output a warning (A.911) if vibration is detected.
2 Output an alarm (A.520) if vibration is detected.
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)