B.3 Parameter Table
402 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
n L7: Torque Limit
n L8: Drive Protection
No. (Addr.) Name Description Setting Page
L7-01
(4A7H)
Forward Torque Limit
Sets the torque limit value as a percentage of the motor rated torque. Four individual quadrants
can be set.
Default: 200%
Min: 0%
Max: 300%
228
L7-02
(4A8H)
Reverse Torque Limit
Default: 200%
Min: 0%
Max: 300%
228
L7-03
(4A9H)
Forward Regenerative Torque
Limit
Default: 200%
Min: 0%
Max: 300%
228
L7-04
(4AAH)
Reverse Regenerative Torque
Limit
Default: 200%
Min: 0%
Max: 300%
228
L7-06
(4ACH)
Torque Limit Integral Time
Constant
Sets the integral time constant for the torque limit.
Default: 200 ms
Min: 5 ms
Max: 10000 ms
228
L7-07
(4C9H)
Torque Limit Control Method
Selection during Accel/Decel
0: Proportional control (changes to integral control at constant speed). Use this setting when
acceleration to the desired speed should take precedence over the torque limit.
1: Integral control. Set L7-07 to 1 if the torque limit should take precedence.
Default: 0
Min: 0
Max: 1
228
L7-16
(44DH)
Torque Limit Process at Start
0: Disable
1: Enable
Default: 0
Min: 0
Max: 1
229
No. (Addr.) Name Description Setting Page
L8-01
(4ADH)
Internal Dynamic Braking Resistor
Protection Selection (ERF type)
0: Resistor overheat protection disabled
1: Resistor overheat protection enabled
Default: 1
Min: 0
Max: 1
229
L8-02
(4AEH)
Overheat Alarm Level
An overheat alarm will occur if the heatsink temperature exceeds the level set in L8-02.
Default:
<24>
Min: 50°C
Max: 150°C
229
L8-03
(4AFH)
Overheat Pre-Alarm Operation
Selection
0: Ramp to stop. A fault is triggered.
1: Coast to stop. A fault is triggered.
2: Fast Stop. Decelerate to stop using the deceleration time in C1-09. A fault is triggered.
3: Continue operation. An alarm is triggered.
Default: 3
Min: 0
Max: 3
229
L8-05
(4B1H)
Input Phase Loss Protection
Selection
Selects the detection of input current phase loss, power supply voltage imbalance, or main
circuit electrolytic capacitor deterioration.
0: Disabled
1: Enabled (software detection only)
4: Enabled (both software and hardware detection)
Default: 1
Min: 0
Max: 4
230
L8-07
(4B3H)
Output Phase Loss Protection
Selection
0: Disabled
1: Enabled (triggered by a single phase loss)
2: Enabled (triggered when two phases are lost)
Default: 0
Min: 0
Max: 2
230
L8-09
(4B5H)
Output Ground Fault Detection
Selection
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
230
L8-10
(4B6H)
Heatsink Cooling Fan Operation
Selection
0: During run only. Fan operates only during run and for L8-11 seconds after stop.
1: Fan always on. Cooling fan operates whenever the drive is powered up.
Default: 0
Min: 0
Max: 1
231
L8-11
(4B7H)
Heatsink Cooling Fan Off Delay
Time
Sets a delay time to shut off the cooling fan after the Run command is removed when L8-10 = 0.
Default: 60 s
Min: 0 s
Max: 300 s
231
L8-12
(4B8H)
Ambient Temperature Setting
Enter the ambient temperature. This value adjusts the oL2 detection level.
Default: 40°C
Min: -10°C
Max: 50°C
231
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
L7-01
L7-03
L7-02
L7-04
Output Torque
Positive Torque
REV
Negative Torque
FWD
Motor
r/min
Regeneration
Regeneration
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes