Limits
When the source function is set to voltage, this displays the current limit. When the
source function is set to current, this displays the voltage limit. When the source range
is set to 10 mV or 100 mV, the limit is fixed to 200 mA (you cannot change this value). In
these situations, “------mA” is displayed for the limit.
Note
In voltage source mode’s 10 mV and 100 mV ranges, the output resistance is approximately 2
Ω
. Therefore, these ranges are not suitable when the GS200 is connected to a load that allows
current to flow (a low-impedance load). Connect a load that allows as little current to flow as
possible (a high-impedance load).
Limiter Indicators
•
is displayed when the high limiter is activated.
•
is displayed when the low limiter is activated.
Program Execution Status
When a program is running, the following items are displayed.
•
Steps:
The step number that is currently being executed.
• Time: The remaining interval time (minutes:seconds.tenths of seconds).
Source Range
The source range that is currently in use is displayed here.
1.3 Display Mode and Displayed Contents