9-40
IM 05P02D41-01EN
9.12.5 Deleting the Program Pattern
Description
This allows specifying the program pattern number to delete.
This allows deleting all programs in the controller.
Clearingallprogrampatterndata:12.2InitializingParameterSettingstoFactoryDefaultValues
SettingDetails
Parameter
symbol
Name
Display
level
Settingrange Menusymbol
CLR.P
Program pattern
clearance
PRO
1 to 2 (4 when the option “/AP” is
specied.)
EDIT
9.12.6 ListoftheErrorCode
Description
Error Indication at Program Pattern Creation and Editing
Error code Errorinformation Causeoferror
ERR01 Pattern creation or editing
is disable during program
operation.
Deleting or copying of the program pattern, or inserting
or deleting of the segment was excuted during program
operation.
ERR22 Segment write error The total number of segments exceeded 20 (40 when
theoption“/AP”isspecied.)
ERR23 Segment insert error New segment cannot be inserted because the number
of segments in a pattern exceeded 20 (40 when the
option“/AP”isspecied.)
ERR32 Patternsourcespecication
error
No pattern exists in the source.
ERR33 Pattern destination
specicationerror
Patterns already exist in the destination.
ERR41 Pattern delete errror The pattern to be deleted does not exist.
Error Codes in Communication
Error code Errorinformation Causeoferror
0 No error Normal end.
1 Pattern creation or editing
is disable during program
operation.
Deleting or copying of the program pattern, or inserting
or deleting of the segment was excuted during program
operation.
2 Pattern number error Thespeciedpatternnumberdoesnotexist.
1to2(4whentheoption“/AP”isspecied.)
3 Segment number error Thespeciedsegmentnumberdoesnotexist.
1to20(40whentheoption“/AP”isspecied.)
22 Segment write error The total number of segments exceeded 20 (40 when
theoption“/AP”isspecied.)
31 Pattern copy error No pattern exists in at the source, or patterns already
exist in the destination.
41 Pattern delete errror The pattern to be deleted does not exist.
9.12 Editing the Program Pattern

Table of Contents

Other manuals for YOKOGAWA UP35A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA UP35A and is the answer not in the manual?

YOKOGAWA UP35A Specifications

General IconGeneral
BrandYOKOGAWA
ModelUP35A
CategoryController
LanguageEnglish

Related product manuals