Statistics F - 3
Communication Diagnostics
USB Reset Count (#15267)-Number of USB Resets. [Occurrences]
USB Suspend Count (#15269)-Number of USB Suspends. [Occurrences]
USB Resume Count (#15271)-Number of USB Resumes. [Occurrences]
USB Enumeration Count (#15273)-Number of USB Enumerations. [Occurrences]
USB Enumeration Count (Attached/Auxiliary Scanners) (#15279)-Total number of USB Enumerations from
peripheral connected scanners. [Occurrences]
Host protocol (#15275)-Indicates the state of the Host interface at time of poll. OK(0) or Fault(1) [List]
Host protocol (#15277)-Number of times the Host interface was in a 'Fault' state. [Faults]
Illumination Diagnostics
Illumination Fault Count (Any Source) (#15134)-Number of times a 'Fault' was detected on Illumination
Sources 1 through 6. Note: If a 'Fault' exists on two Illumination Sources simultaneously, it will only be
counted once. [Faults]
Illumination Source 1 (Left Horizontal) State (#15136)-Indicates the state of Illumination Source. 0K(0) or
Fault: Over-Current(1), Fault: Stuck-On(2), or Fault: Stuck-Off(3). [List]
Illumination Source 1 (Left Horizontal) Fault Count (#15141)-Number of times a 'Fault' was detected on the
illumination Source. [Faults]
Illumination Source 2 (Center Horizontal) – State (#15143)-Indicates the state of illumination Source. OK(0)
or Fault: Over-Current(1), Fault: Stuck-On(2), or Fault: Stuck-Off(3). [List]
Illumination Source 2 (Center Horizontal) - Fault Count (#15148)-Number of times a 'Fault was detected on
the illumination Source. [Faults]
Illumination Source 3 (Right Horizontal) State (#15150)-Indicates the state of Illumination Source. 0K(0) or
Fault: Over-Current(1), Fault: Stuck-On(2), or Fault: Stuck-Off(3). [List]
Illumination Source 3 (Right Horizontal) Fault Count (#15155)-Number of times a 'Fault' was detected on the
illumination Source. [Faults]
Digimarc UPC #15787 N/A N/A N/A
Digimarc EAN/JAN #15798 N/A N/A N/A
Digimarc Other #15776 N/A N/A N/A
Other 1D #15540 #15545 #15543 #15544
Other 2D #15547 #15552 #15550 #15551
Other #15554 #15559 #15557 #15558
Table F-1 Decode Time and Count Statistic/Parameter Numbers (Continued)