Statistics F - 5
Scale Diagnostics
•
Scale is Calibrated (#15241)-Indicates if the scale is calibrated. Yes(0) or No(1). [List]
•
Scale is Calibrated – Count (#15239)-Number of times the scale was calibrated. [Calibrations]
•
Total "Get Weight" requests issued (#15213)-Number of times an application requested the
'Scale-Get-Weight' command. [Occurrences]
•
Stable weight count on "Get Weight" (#15219)-Upon an application requesting 'Scale-Get-Weight' this is the
number of times the scale was reporting 'Stable weight'. [Occurrences]
•
Zero weight count "Get Weight" (#15217)-Upon an application requesting 'Scale-Get-Weight' this is the
number of times the scale was reporting 'Zero weight'. [Occurrences]
•
Unstable weight count on "Get Weight" (#15315)-Upon an application requesting 'Scale-Get-Weight' this is
the number of times the scale was reporting 'Unstable'. [Occurrences]
•
Slight overweight count on "Get Weight" (#15221)-Upon an application requesting 'Scale-Get-Weight' this is
the number of times the scale was reporting 'Slight Overweight'. [Occurrences]
•
Extreme overweight condition count "Get Weight" (#15231)-Upon an application requesting
'Scale-Get-Weight' this is the number of times the scale was reporting 'Extreme Overweight'. [Occurrences]
•
Underweight count on "Get Weight" (#15215)-Upon an application requesting 'Scale-Get-Weight' this is the
number of times the scale was reporting 'Underweight'. [Occurrences]
•
Zero button press count during weight below Zero (#15223)-Upon pressing the 'Scale Zero Button' this is the
number of times the scale was reporting 'Weight Below 0'. [Occurrences]
•
Zero button press count during weight above Zero (#15225)-Upon pressing the 'Scale Zero Button' this is the
number of times the scale was reporting 'Weight Above 0'. [Occurrences]
•
Calibration Process – State (#15317)-There was an error during the Scale calibration process. [List]
•
Calibration Process - Fault Count (#15233)-Number of times 'Scale-Calibration' failed. [Faults]
•
Scale Communication – State (#15247)-Indicates the state of the scale interface. OK(0) or Fault(1). [List]
•
Scale Communication - Fault Count (#15249)-Number of times the scale interface was at 'Fault'. [Faults]
•
Scale Motion – State (#15255)-Indicates the scale detects that the weighing surface is not moving ("No
Motion") and therefore can achieve a stable weight. OK(0) or Fault(1). [List]
•
Scale Motion - Fault Count (#15257)-Number of times the scale was at 'Fault'. [Faults]
•
Internal Scale – State (#15305)-Indicates the scale has encountered an internal 'Fault'. OK(0) or Fault(1).
[List]
•
Internal Scale - Fault Count (#15307)-Number of times the scale encountered an internal 'Fault'. [Faults]
•
Zero Button Press – State (#15227)-Indicates if the last 'Scale Zero Button' press was successful.
Successful(0) or Failed to Zero(1). [List]
•
Zero Button Press - Fault Count (#15229)-Number of times the 'Scale Zero Button' press Failed to Zero.
[Faults]
•
Outside Zero Drift Threshold – State (#15235)-Indicates if the scale is currently within drift limits. OK(0) or
Fault(1). [List]
•
Outside Zero Drift Threshold - Fault Count (#15237)-Number of times the scale drift limits was at 'Fault'.
[Faults]
•
Pole Display – State (#15251)-Indicates the state of the scale pole display interface. OK(0) or Fault(1). [List]
•
Pole Display - Fault Count (#15253)-Number of times the scale pole display interface was at 'Fault'. [Faults]