Host Interfaces and Cable Pinouts 2 - 31
RS-232 Host Types (continued)
RS-232 Host -NCR Variant
Scan the barcode below to enable the NCR variant of the RS-232 host.
NCR Variant
IMPORTANTThere are several parameter options available with the NCR variant for RS-232. Refer to the MP7000
Scanner Scale Barcode Programming Guide (p/n MN-002912-xx) to manage the following NCR
related parameters:
NCR Use Prefix
NCR Prefix
NCR Suffix
NCR Use BCC
NCR Interface.

Table of Contents

Other manuals for Zebra MP7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra MP7000 and is the answer not in the manual?

Zebra MP7000 Specifications

General IconGeneral
TypeBuilt-in bar code reader
Sensor typeCMOS
Scanner type1D/2D
Linear (1D) barcodes supportedCodabar, Code 128, Code 32, Code 39, Code 93, Discrete 2 of 5, EAN 128, EAN-13, EAN-8, GS1 DataBar, GS1 DataBar Expanded, GS1 DataBar Omnidirectional, GS1 Databar Limited, Interleaved 2 of 5, JAN, MSI, Plessey, Trioptic, UPC-A, UPC-E
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Han Xin, Micro QR Code, MicroPDF417, PDF417, QR Code
Input voltage90 - 264 V
Input frequency47 - 63 Hz
Power source typeAC, RS-232, USB
Power consumption (standby)3 W
Power consumption (typical)5.5 W
Standard interfacesRS-232, RS-485, USB
Connectivity technologyWired
Keys quantity4 keys
Product colorBlack, Stainless steel
LED indicatorsYes
Image formats supportedBMP, JPEG
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width292 mm
Height128 mm
Weight5700 g