Site Preparation and Installation 3 - 3
Electrical Power Considerations
The MP70XX may be powered from two different sources:
• POS Equipment
• IBM register with powered Port 9B interface (using p/n CBA-M51-S16PAR accessory cable)
• Any register with powered USB interface - 12V only (using p/n CBA-U52-S16PAR accessory cable).
• AC/DC power cube (p/n PWR-BGA12V50W0WW), country specific IEC Line Cord, DC Power Cord (p/n 
CBL-DC-388A1-01). 
Figure 3-2    Power Supply
If using the AC/DC accessory power supply, a 115V/230V outlet must be available in the checkstand near the 
scanner.
Grounding
All POS equipment should be properly grounded, and only a three prong IEC style line cord should be used with 
the AC/DC accessory power supply.
If you are unsure how to verify proper ground of equipment in the checkstand ask a qualified electrician to review 
the equipment installation.
NOTE In an effort to eliminate a possible safety hazard all metal parts of a metal checkstand must be electrically 
grounded.
4.3 in.(+/- 0.02)
110.0 mm (+/- 0.5)
1.3 in.(+/- 0.02)
33.0 mm (+/- 0.5)
2.4 in.(+/- 0.02)
62.0 mm (+/- 0.5)
4.3 in.(+/- 0.02)
110.0 mm (+/- 0.5)