Site Preparation and Installation 3 - 9
Figure 3-6 Dual Scale Display - Dimensions; Display Rotates Independently (Approximately 290
o
)
Getting Started
For an existing Scale Display from an old scanner:
Unscrew the unit, disconnect its cable from scanner, then remove the unit and cables.
In same location, (or in a new location as specified by the retailer and/or local weights and measures law)
replace with the Zebra Scale Display.
For a new installation:
Identify the location to install the Scale Display. Identify the location to place the Scale Display based on
counter design and viewing angle. Place the unit where it cannot impede access to scanned items being
swept over the MP70XX, payment terminals, printer validation and paper roll slots, access to replace
consumables (rolls) etc.
Drill the required holes where the display is to be mounted.
a. The 19 mm (3/4 in.) diameter hole is optional, to be used as a through hole for the cable pass-through.
b. The other two holes are pilot holes for the mounting screws and should be made to a diameter of 2.4 mm
(3/32 in.) and a depth of 25 mm (.98 in.). See the template for hole spacing.
NOTE BOTH cashier and customer need to see the weight value displayed.
NOTE The cable can also be routed on top of the counter via the notch in the base of the display. See the template
for hole spacing.