GDP-32
II
INSTRUCTION MANUAL
May 2002 Section 11, Page 20
4. Single station tensor measurements:
Data displayed on LCD after acquisition:
Data from
Tx Antenna #1
Data from
Tx Antenna #2
Remember, for full tensor measurements we need to make identical measurements from two
orthogonally oriented transmitters. Hence the identical channel notation for the two transmitters.
We identify the two different sources by using the Tx field as shown, and generating separate
files with our data processing programs.
For this example, an ANT/1 single axis magnetic antenna, Serial Number 32, is used for Hz. All
other notation is as above in the previous examples.
Tx 1 Rx 1 N OUT
16 Hz 256 Cycles Tx Curr 25
CH Sta/Ant rho E
φ
φφ
φ
-H
φ
φφ
φ
SEM GGGA
1Ex 1RHOxy
1
Ex
1
-Hy
1
φ
φφ
φ
2Hy 141
3Ey 1RHOyx
1
Ey
1
-Hx
1
φ
φφ
φ
4Hx 142
5Hz 320HzMagHz
φ
φφ
φ
6OFF
7OFF
8OFF
Tx 2 Rx 1 N OUT
16 Hz 256 Cycles Tx Curr 21
CH Sta/Ant rho E
φ
φφ
φ
-H
φ
φφ
φ
SEM GGGA
1Ex 1RHOxy
1
Ex
1
-Hy
1
φ
φφ
φ
2Hy 141
3Ey 1RHOyx
1
Ey
1
-Hx
1
φ
φφ
φ
4Hx 142
5Hz 320HzMagHz
φ
φφ
φ
6OFF
7OFF
8OFF