Name Function
block
SPA
address
Description
ExcOpen=00,
ExcClose=01, so on.
SCSWI15 1 I 5442 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI16 1 I 5466 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI17 1 I 5490 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI18 1 I 5514 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI19 1 I 5536 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI20 1 I 5562 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI21 1 I 5585 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI22 1 I 5610 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI23 1 I 5634 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI24 1 I 5658 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI25 1 I 5682 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI26 1 I 5706 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI27 1 I 5730 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI28 1 I 5754 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI29 1 I 5778 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI30 1 I 5802 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI31 1 I 5826 SPA parameters for operate (Open/
Close) command
ExcOpen=00,
ExcClose=01, so on.
SCSWI32 1 I 5850 SPA parameters for operate (Open/
Close) command
Sub Value SXCBR01 2 I 7854 SPA parameter for position to be
substituted
Note: Send the value before Enable
Sub Value SXCBR02 2 I 7866 SPA parameter for position to be
substituted
Sub Value SXCBR03 2 I 7884 SPA parameter for position to be
substituted
Sub Value SXCBR04 2 I 7904 SPA parameter for position to be
substituted
Table continues on next page
1MRK505222-UUS C Section 17
Station communication
1019