AND
a
b
b>a
Selected voltage
PickupVolt_UV1
Operation_UV1=On
BLKUV1
Inverse time
selected
en05000752_ansi.vsd
Inverse
0-DEF
DEF time
selected
OR
PU_UV1
TRUV1
AND
BLKTRUV1
0
ANSI05000752 V1 EN
Figure 298: Simplified internal logic diagram for built-in first undervoltage step UV1 (step UV2 has the same
internal logic)
10.1.3 Function block
ANSI05000372-2-en.vsd
CVGAPC
I3P*
V3P*
BLOCK
BLKOC1
BLKOC1TR
ENMLTOC1
BLKOC2
BLKOC2TR
ENMLTOC2
BLKUC1
BLKUC1TR
BLKUC2
BLKUC2TR
BLKOV1
BLKOV1TR
BLKOV2
BLKOV2TR
BLKUV1
BLKUV1TR
BLKUV2
BLKUV2TR
TRIP
TROC1
TROC2
TRUC1
TRUC2
TROV1
TROV2
TRUV1
TRUV2
PICKUP
PU_OC1
PU_OC2
PU_UC1
PU_UC2
PU_OV1
PU_OV2
PU_UV1
PU_UV2
BLK2ND
DIROC1
DIROC2
VDIRLOW
CURRENT
ICOSFI
VOLTAGE
VIANGLE
ANSI05000372 V2 EN
Figure 299: CVGAPC function block