17 MAINTENANCE / DIAGNOSTICS / REPAIRS
17.1 Error messages
MESSAGE ON DISPLAY CAUSE REMEDY JOB MODE
Drive!
Machine stopped
Main switch ON with machine stopped
• Start the machine.
• Move main switch downwards
(position OFF)
Master ON
+
Automatic
adjustment ON
Connection to ECU not detected!
Communication problems between monitor and
control unit (ECU)
• Check condition of connection cables
(and connectors) between monitor and control unit
(par. 5.2)
--
The cables are damaged • Replace the cable --
GPS receiver not connected!
Wrong connection of receiver cable to Delta 80 • Check connection to receiver (par. 5.2) --
The receiver connection cable is damaged • Replace the cable --
The receiver is damaged • Replace the receiver --
Insufficient GPS signal quality!
The position and number of satellites do not
allow a suitable driving precision
Wait for signal strength to improve --
GPS receiver gives invalid data!
The receiver is establishing a connection to the
satellites
Wait for connection --
DGPS correction not available!
DGPS signal unavailable in the working area • Disable DGPS correction (par. 10.3.1) --
DGPS connecting Wait for connection --
Omnistar correction missing!
Acquiring OmniSTAR
®
signal
Wait until OmniSTAR
®
signal acquisition stage is
completed
--
The connected GPS receiver does not support
the OmniSTAR
®
signal
• Disable OmniSTAR
®
correction (par. 10.3.4) --
Activate pump!
Missing flowrate
Main switch ON but rate at zero • Start the pump and move the machine.
Master ON
+
Automatic
adjustment ON
Minimum tank level reached!
Tank level is lower than the set reserve value • Fill the tank (par. 15.3)
Master ON
Minimum value was not set
correctly
• Check set reserve value (par. 10.1.10)
Maximum tank level reached!
Tank level reached set maximum value • Stop lling the tank (par. 15.3) --
Automatic regulation blocked!
Pressure does not reach set value • Increase driving speed
Master ON
+
Automatic
adjustment ON
Limit was not set correctly • Check set limit (par. 10.1.12)
CONTINUES