MAINTENANCE / DIAGNOSTICS / REPAIRS
END OF PAR. 17.1 ERROR MESSAGES
MESSAGE ON DISPLAY CAUSE REMEDY JOB MODE
Switch box connection not detected!
Communication problems between monitor and
switches
• Check condition of connection cables
(and connectors) between monitor and switch box
--
The cables are damaged • Replace the cable
Seletron connection failed!
One or more spraying points do not respond
• Identify the unrecognized spraying point with the
dedicated menu
Device status > Status of the Seletron
system (par. 10.8)
• Check that the corresponding spraying point is
connected correctly
• Check condition of harness on the
corresponding spraying point
--
Seletron system error!
Low supply voltage on one or more spraying
points
Check battery voltage level --
• Identify the unrecognized spraying point with the
dedicated menu
Device status > Status of the Seletron
system (par. 10.8)
• Check condition of harness on the
corresponding spraying point
--
Job origin too far away!
The current position is too far away from the job
origin.
• Redene the job origin. --
ECU power supply voltage out of
range!
Power voltage supply is not within the required
range (9÷16 V)
Check power supply --
External battery power supply missing!
Power supply is not feeding any voltage at all Check power supply --
Boom line 1:
Too high power consumption!
Boom 1 power line detected a high absorption
Check the Seletron, connection cable and
connector status
--
Boom line 2:
Too high power consumption!
Boom 2 power line detected a high absorption
Check the Seletron, connection cable and
connector status
--
Regulation line:
Too high power consumption!
The power line controlling the main valve and the
regulation valve detected a high absorption
Check the valve, connection cable and connector
status
--
Hydraulic line:
Too high power consumption!
The power line controlling the hydraulic functions
detected a high absorption
Check the valve, connection cable and connector
status
--